The Jovial JTE ShortStop Cable Fault Finder
|
|
Power: 4 AA alkaline batteries, 50 hours of battery life. Low Battery Indicator flashes when battery voltage falls below 4.1 volts. Input Protection: 250V RMS AC, continuous. Cable Impedance: 25 to 330 ohms with auto-compensation. Maximum Cable Length: Approximately 2500 feet. The unit will visually and audibly indicate if the cable is too long to be correctly measured. Representative
approximate maximum cable lengths are:
Minimum Length: Zero feet. Length Accuracy:
+/- 2 feet for cables shorter than 10 feet.
High Voltage Detection: An AC voltage of more than 30 Volts RMS will trigger the High Voltage Warning. Measurement Rate: Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable type. Measurement Technology: Time Domain Reflectometry (TDR) with 50 ohm drive impedance, 6 volt maximum pulse height, 8 µs maximum pulse width. Tone Injection: Approximately 1kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristic is changed when cable is momentarily shorted. Cable Types: Virtually all two or more conductor cables. Environment: 0° to +55°C operating, 0° to +70°C storage, 0 to 80% humidity. VOP: Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are changed. Weight: 1 pound, with batteries and clip leads. Size: 7.4" tall, 1.5" thick, 2.75" wide. Limited Warranty: For a period of one year from the date of purchase. Copyright Notice: All rights reserved. Trademark Notice: ShortStop™, PowerTone™, and Can't Find Your Shorts?™ are registered trademarks of Jovial Test Equipment, Inc. 2719 Encinal Avenue, Alameda, CA Patents Pending
|
ShortStop
| QuickStart
| Manual
| FAQ's
| Applications
| Measurements
Home
Back